Associated Environmental Systems offers a range of prefabricated, tight-tolerance environmental walk-in rooms that are easy to ship and install. Major features include:
Refrigeration Systems
AES supplies a refrigeration package that supports the load demands of the Walk-In Environmental Room.
All Walk-in Room Systems
Up to 5 HP units can be mounted on the roof of the walk-in room. Larger units are installed on the floor next to the room.
Comprehensive piping diagrams, schematics, and charging data are available for our environmental walk-in rooms.
Walk-in Room Construction
Rooms
are constructed of prefabricated metal tongue and groove sectional
panels. An assembled room has continuous steel perimeters to hold
panels tightly in place.
Panel features include:
Viewing Windows The standard multipane window has a 14" by 23" viewing area. Thermostatically controlled heater wire in the window casing minimizes condensation and frost formation on the window surface. Custom size windows are available.Lighting All lighting fixtures are vapor proof and sealed. Both
incandescent and flurorescent lighting fixtures are available.
Incandescent lighting is recommended for high temperature units operating above +110°F and low temperature units operating below 0°F. Forced Air Circulation Systems All walk-in rooms incorporate forced air circulation. Differences in the size of the test chamber and its internal configuration are accommodated by various airflow patterns, including horizontal, vertical, or a combination of both. These provide an even distribution of air and tight temperature control. Noise is also a consideration.
The air circulation systems use external heavy duty motors to distribute air evenly and constantly recirculate it, maintaining uniform and accurate temperatures and humidity. The high quality motors have internal cooling fans, protectors, and stainless steel shafts. Aluminum or stainless steel squirrel cage blowers circulate the air. All mixing is within a plenum that is external to the walk-in room work area.
In tight tolerance environmental walk-in rooms, air must be evenly distributed and constantly recirculated at a higher than normal rate in order to maintain uniformity and accuracy. A portion of one wall of the room is devoted to a conditioning plenum. Air is drawn into the lower part of the plenum through a set of cleanable filters, across an evaporator coil and vertically across electric heaters. The air then enters centrifugal fans and is discharged into a perforated ceiling plenum. The air flows vertically downward in the room and is returned horizontally through the cleanable filters to the wall plenum. Electric Heating System The combination of airflow, instrument response, and fast-reacting heaters provides very accurate and straight line control of temperatures.
Air is passed over the fast response, low watt density heaters with ceramic cores. This type of system provides very accurate air and humidity control. A separate instrument precisely controls the heat level.
The heating systems have a long life and are very reliable, with no down time. Instrumentation Instrumentation consists of either single or two-channel microprocessor programmers with an accuracy of ±.25°C or better at the sensor. The sensors are fast acting 100 Ohm. platinum type.
Other options include: RS-232, IEEE-488 interface. Safety Standard is a redundant control circuit with its own controller and failsafe contactor. To prevent thermal runaway, the safety control shuts off power to the heater circuit and the circulation blowers continue to distriibute heat within the room. This feature is particularly important if there are heat-generating items in the walk-in room. When the temperature goes down, the safety control closes and power is restored to the heaters.
Other available safety options are: High Temperature Safety with Complete Shut Down of Room with Manual Reset and Visual Indication, Low Temperature Safety with Complete Shut Down of Room with Manual Reset and Visual Indication, Both High and Low Temperature Safety with Manual Reset on Both and Visual Indication, Audible Alarm, and Remote Station Alarms. Electrical Requirements Standard power requirements include 208V 3PH 60HZ, 220/240V 3PH 60HZ, 460V 3PH 60HZ, 208/220V 1PH 60HZ. Other power requirements are available upon request.Temperature Ranges Various ranges can be provided, including fast change rates with your product load. Ranges from -73°C (-100°F) to +85°C are available.
Humidity Standard ranges available are: 20% to 95% ±5% RH. 10% to 98% ±2% RH. Different ranges available including special dehumidity ranges to 5% RH.Humidity System Two Humidity systems are standard:
The conditioned Fine Mist System uses your local water supply. Steam is created within a plenum outside the room area by spraying a fine mist over a stainless steel sheath-type heater. The circulation system carries this steam throughout the walk-in room.
The Steam Generator System uses an external self-contained steam generator with all necessary safety and water level controls to provide humidities to saturation point within the walk-in room.
|
|||
Contact us at (978) 772-0022 or Sales@AssociatedEnvironmental.com